Industrial hazardous and nonhazardous waste and medical infectious waste
Industrial hazardous and nonhazardous waste and medical infectious waste
10 Apr
2023

Industrial hazardous and nonhazardous waste and medical infectious waste   Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC) Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour Feed Capacity(Average) 600kg/feeding 400kg/feeding Control […]


Incinerator for Medium type Hospital 100 -200 Kg per day
12 Aug
2021

Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy […]





3layer Facial mask machine
06 Apr
2020

Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected]  Face Mask Machine for Coronavirus Disease COVID-19 平面口罩机参数: Semi-Automatic Mask Machine […]


Medical Waste Incinerator for Coronavirus Disease COVID-19
02 Apr
2020

HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type […]


Incinerator wet scrubber
31 Dec
2019

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201   Website: www.hiclover.com  Email: [email protected][email protected]    Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.   The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.   Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell.   The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation.   In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.


incinerator shipping
27 Nov
2019

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. It features unique and advanced merits with compact size, high burning effect, reasonable burning technology, high degree of non-harm etc.It is an ideal choice for waste treatment of hospitals, hotels and various areas.Features: (1)   Gasifiedpyrolysis incineration is used for burning many kinds of waste.(2)   Waste can be burned once everyday by gasified incineration.(3)   Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust,dioxin etc.(4)   Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution. (5)   Compact structure and small land occupation. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) […]


50 kg/hour capacity incinerators
12 Nov
2019

Burning Rate: 50kgs/hrFeed Capacity: 150kgsPrimary Combustion Chamber: 900 litresSecondary Combustion Chamber: 300 litresMix Combustion Chamber: YesSmoke Filter Chamber: YesFeed Mode: ManualPower: 0.7KwFuel Type: Diesel Oil/ Natural Gas/LPGInternal Dimensions: 120 x 90 x 85cm (primary chamber)External Dimensions: 200 x 160 x 310cm (without chimney)Burning Efficiency: >98% Capacity: 50kg/hour 50-100kgs/hour Low speed low noise Yes Blades are abrasion resistant graded steel- duly heat treated Yes Charging door and waste removal doors are  easy operable complete with door opening safety mechanism thus preventing any aerosol escaping Yes Provided with PLC Panel and emergency stop switch Electric ControlBranded Stainless Steel/ Powder coated metal Electric Needle and Syringe Destroyer, (220/240 V, 50 Hz) Plastic outer covering. 220V±10%Type of Electrodes used: Copper with silver plated. Destruction Rate in, seconds/Needle: 2 to 3 seconds per needle depending on the size of the needle. 1 to 3 seconds per needle depending on the size of the needle.Thickness & Length of Needle Recommended : Dia. 0.4 mm to 1.0 mm, Length 12.5mm to 80mm. Yes Tray Capacity No. of syringes & Needles: 200 Nos. of destroyed syringe hubs and needle SWRF can be collected in drawer. Tray Capacity No. of syringes & Needles: 50 Nos.Safety Features, provided: Cartridge glass fuse of 2 Amps capacity is provided. Overheating protection temperature: 95℃Quantity: 1,800 red pes, 1,800 blue pes and 1,800 yellow pes Plastic Bags of HDPL, LLPE, DP should be biodegradable not reused plastic, bags should be superior quality of thickness of 50 micron or more thickness, non chlorinated plastic. Bags should be Autoclavble & Puncture proof […]